Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 18.545
Filter
1.
BMC Microbiol ; 24(1): 143, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38664628

ABSTRACT

BACKGROUND: Broiler chickens are frequently colonized with Extended-Spectrum Beta-Lactamase- (ESBL-) and plasmid mediated AmpC Beta-Lactamase- (pAmpC-) producing Enterobacterales, and we are confronted with the potential spread of these resistant bacteria in the food chain, in the environment, and to humans. Research focused on identifying of transmission routes and investigating potential intervention measures against ESBL- and pAmpC- producing bacteria in the broiler production chain. However, few data are available on the effects of cleaning and disinfection (C&D) procedures in broiler stables on ESBL- and pAmpC- producing bacteria. RESULTS: We systematically investigated five broiler stables before and after C&D and identified potential ESBL- and pAmpC- colonization sites after C&D in the broiler stables, including the anteroom and the nearby surrounding environment of the broiler stables. Phenotypically resistant E. coli isolates grown on MacConkey agar with cefotaxime were further analyzed for their beta-lactam resistance genes and phylogenetic groups, as well as the relation of isolates from the investigated stables before and after C&D by whole genome sequencing. Survival of ESBL- and pAmpC- producing E. coli is highly likely at sites where C&D was not performed or where insufficient cleaning was performed prior to disinfection. For the first time, we showed highly related ESBL-/pAmpC- producing E. coli isolates detected before and after C&D in four of five broiler stables examined with cgMLST. Survival of resistant isolates in investigated broiler stables as well as transmission of resistant isolates from broiler stables to the anteroom and surrounding environment and between broiler farms was shown. In addition, enterococci (frequently utilized to detect fecal contamination and for C&D control) can be used as an indicator bacterium for the detection of ESBL-/pAmpC- E. coli after C&D. CONCLUSION: We conclude that C&D can reduce ESBL-/pAmpC- producing E. coli in conventional broiler stables, but complete ESBL- and pAmpC- elimination does not seem to be possible in practice as several factors influence the C&D outcome (e.g. broiler stable condition, ESBL-/pAmpC- status prior to C&D, C&D procedures used, and biosecurity measures on the farm). A multifactorial approach, combining various hygiene- and management measures, is needed to reduce ESBL-/pAmpC- E. coli in broiler farms.


Subject(s)
Bacterial Proteins , Chickens , Disinfection , Escherichia coli , Farms , beta-Lactamases , Animals , beta-Lactamases/genetics , beta-Lactamases/metabolism , Chickens/microbiology , Escherichia coli/genetics , Escherichia coli/drug effects , Escherichia coli/isolation & purification , Disinfection/methods , Bacterial Proteins/genetics , Bacterial Proteins/metabolism , Escherichia coli Infections/veterinary , Escherichia coli Infections/microbiology , Escherichia coli Infections/transmission , Poultry Diseases/microbiology , Poultry Diseases/prevention & control , Anti-Bacterial Agents/pharmacology , Phylogeny , Plasmids/genetics , Multilocus Sequence Typing , Whole Genome Sequencing
2.
World J Urol ; 42(1): 252, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652324

ABSTRACT

BACKGROUND: To prevent infectious complications after transrectal ultrasound-guided prostate biopsy (TRUS-PB), some studies have investigated the efficacy of rectal disinfection using povidone-iodine (PI) and antibiotic prophylaxis (AP). OBJECTIVE: To summarize available data and compare the efficacy of rectal disinfection using PI with non-PI methods prior to TRUS-PB. EVIDENCE ACQUISITION: Three databases were queried through November 2023 for randomized controlled trials (RCTs) analyzing patients who underwent TRUS-PB. We compared the effectiveness of rectal disinfection between PI groups and non-PI groups with or without AP. The primary outcomes of interest were the rates of overall infectious complications, fever, and sepsis. Subgroups analyses were conducted to assess the differential outcomes in patients using fluoroquinolone groups compared to those using other antibiotics groups. EVIDENCE SYNTHESIS: We included ten RCTs in the meta-analyses. The overall rates of infectious complications were significantly lower when rectal disinfection with PI was performed (RR 0.56, 95% CI 0.42-0.74, p < 0.001). Compared to AP monotherapy, the combination of AP and PI was associated with significantly lower risk of infectious complications (RR 0.54, 95% CI 0.40-0.73, p < 0.001) and fever (RR 0.47, 95% CI 0.30-0.75, p = 0.001), but not with sepsis (RR 0.49, 95% CI 0.23-1.04, p = 0.06). The use of fluoroquinolone antibiotics was associated with a lower risk of infectious complications and fever compared to non-FQ antibiotics. CONCLUSION: Rectal disinfection with PI significantly reduces the rates of infectious complications and fever in patients undergoing TRUS-PB. However, this approach does not show a significant impact on reducing the rate of sepsis following the procedure.


Subject(s)
Anti-Infective Agents, Local , Disinfection , Povidone-Iodine , Prostate , Rectum , Humans , Povidone-Iodine/therapeutic use , Povidone-Iodine/administration & dosage , Male , Disinfection/methods , Anti-Infective Agents, Local/therapeutic use , Anti-Infective Agents, Local/administration & dosage , Prostate/pathology , Antibiotic Prophylaxis/methods , Image-Guided Biopsy/methods , Prostatic Neoplasms/pathology
3.
Environ Sci Technol ; 58(15): 6552-6563, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38571383

ABSTRACT

Extracellular polymeric substances (EPS) ubiquitously encapsulate microbes and play crucial roles in various environmental processes. However, understanding their complex interactions with dynamic bacterial behaviors, especially during the disinfection process, remains very limited. In this work, we investigated the impact of EPS on bacterial disinfection kinetics by developing a permanent EPS removal strategy. We genetically disrupted the synthesis of exopolysaccharides, the structural components of EPS, in Pseudomonas aeruginosa, a well-known EPS-producing opportunistic pathogen found in diverse environments, creating an EPS-deficient strain. This method ensured a lasting absence of EPS while maintaining bacterial integrity and viability, allowing for real-time in situ investigations of the roles of EPS in disinfection. Our findings indicate that removing EPS from bacteria substantially lowered their susceptibility threshold to disinfectants such as ozone, chloramine B, and free chlorine. This removal also substantially accelerated disinfection kinetics, shortened the resistance time, and increased disinfection efficiency, thereby enhancing the overall bactericidal effect. The absence of EPS was found to enhance bacterial motility and increase bacterial cell vulnerability to disinfectants, resulting in greater membrane damage and intensified reactive oxygen species (ROS) production upon exposure to disinfectants. These insights highlight the central role of EPS in bacterial defenses and offer promising implications for developing more effective disinfection strategies.


Subject(s)
Disinfectants , Disinfection , Disinfection/methods , Extracellular Polymeric Substance Matrix , Disinfectants/pharmacology , Chlorine/pharmacology , Kinetics
4.
J Appl Microbiol ; 135(4)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38573833

ABSTRACT

In the 1940s and 1950s, researchers seeking safe and novel ways to eliminate airborne pathogens from enclosed spaces, investigated glycol vapours as a method of disinfection. More recently, the COVID-19 pandemic highlighted the need for a non-toxic aerial disinfectant that can be used in the presence of people. This scoping review is intended to analyse the early and more recent literature on glycol disinfection, scrutinizing the methodologies used, and to determine if the use of glycols as modern-day disinfectants is justified PRISMA-ScR guidelines were used to assess the 749 articles retrieved from the Web of Science platform, with 46 articles retained after the search strategy was applied. Early studies generally demonstrated good disinfection capabilities against airborne bacteria and viruses, particularly with propylene glycol (PG) vapour. Vapour pressure, relative humidity, and glycol concentration were found to be important factors affecting the efficacy of glycol vapours. Contact times depended mainly on the glycol application method (i.e. aerosolization or liquid formulation), although information on how glycol efficacy is impacted by contact time is limited. Triethylene glycol (TEG) is deemed to have low toxicity, carcinogenicity, and mutagenicity and is registered for use in air sanitization and deodorization by the US Environmental Protection Agency. Glycols are also used in liquid formulations for their antimicrobial activity against a wide range of microorganisms, although when used as a non-active excipient in products, their contribution to antimicrobial efficacy is rarely assessed. The appropriate use of liquid glycol-containing formulations was found to positively impact the antimicrobial capabilities of disinfectants when used at temperatures <0, food preservatives, and dental medicaments. Providing modern delivery technology can accurately control environmental conditions, the use of aerosolized glycol formulations should lead to successful disinfection, aiding infection prevention, and control regimens.


Subject(s)
Anti-Infective Agents , Disinfectants , Humans , Pandemics/prevention & control , Disinfectants/pharmacology , Disinfection/methods , Anti-Infective Agents/pharmacology , Propylene Glycol/pharmacology , Gases
5.
Environ Sci Technol ; 58(15): 6793-6803, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38574343

ABSTRACT

Current disinfection processes pose an emerging environmental risk due to the ineffective removal of antibiotic-resistant bacteria, especially disinfection residual bacteria (DRB) carrying multidrug-resistant plasmids (MRPs). However, the characteristics of DRB-carried MRPs are poorly understood. In this study, qPCR analysis reveals that the total absolute abundance of four plasmids in postdisinfection effluent decreases by 1.15 log units, while their relative abundance increases by 0.11 copies/cell compared to investigated wastewater treatment plant (WWTP) influent. We obtain three distinctive DRB-carried MRPs (pWWTP-01-03) from postdisinfection effluent, each carrying 9-11 antibiotic-resistant genes (ARGs). pWWTP-01 contains all 11 ARGs within an ∼25 Kbp chimeric genomic island showing strong patterns of recombination with MRPs from foodborne outbreaks and hospitals. Antibiotic-, disinfectant-, and heavy-metal-resistant genes on the same plasmid underscore the potential roles of disinfectants and heavy metals in the coselection of ARGs. Additionally, pWWTP-02 harbors an adhesin-type virulence operon, implying risks of both antibiotic resistance and pathogenicity upon entering environments. Furthermore, some MRPs from DRB are capable of transferring and could confer selective advantages to recipients under environmentally relevant antibiotic pressure. Overall, this study advances our understanding of DRB-carried MRPs and highlights the imminent need to monitor and control wastewater MRPs for environmental security.


Subject(s)
Disinfectants , Water Purification , Disinfection , Genes, Bacterial , Bacteria/genetics , Anti-Bacterial Agents/pharmacology , Disinfectants/pharmacology , Plasmids/genetics
6.
Food Microbiol ; 121: 104516, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38637078

ABSTRACT

Oxidation-reduction potential (ORP) is commonly used as a rapid measurement of the antimicrobial potential of free chlorine during industrial fresh produce washing. The current study tested the hypothesis that ORP can act as a "single variable" measurement of bacterial (vegetative and endospores) inactivation effectiveness with free chlorine irrespective of the water pH value. This situation has on occasion been assumed but never confirmed nor disproven. Chlorine-dosed pH 6.5 and 8.5 phosphate buffer solutions were inoculated with Escherichia coli (E. coli), Listeria innocua (L. innocua), or Bacillus subtilis (B. subtilis) endospores. ORP, free chlorine (FC), and log reduction were monitored after 5 s (for E. coli and L. innocua) and up to 30 min (for B. subtilis spores) of disinfection. Logistic and exponential models were developed to describe how bacteria reduction varied as a function of ORP at different pH levels. Validation tests were performed in phosphate buffered pH 6.5 and 8.5 cabbage wash water periodically dosed with FC, cabbage extract and a cocktail of Escherichia coli O157:H7 (E. coli O157:H7) and Listeria monocytogenes (L. monocytogenes). The built logistic and exponential models confirmed that at equal ORP values, the inactivation of the surrogate strains was not consistent across pH 6.5 and pH 8.5, with higher reductions at higher pH. This is the opposite of the well-known free chlorine-controlled bacterial inactivation, where the antibacterial effect is higher at lower pH. The validation test results indicated that in the cabbage wash water, the relationship between disinfection efficiency and ORP was consistent with the oxidant demand free systems. The study suggests that ORP cannot serve as a reliable single variable measurement to predict bacterial disinfection in buffered systems. When using ORP to monitor and control the antibacterial effectiveness of the chlorinated wash water, it is crucial to take into account (and control) the pH.


Subject(s)
Escherichia coli O157 , Listeria monocytogenes , Listeria , Disinfection/methods , Chlorine/pharmacology , Chlorine/analysis , Food Contamination/analysis , Food Microbiology , Oxidants , Colony Count, Microbial , Food Handling/methods , Chlorides , Oxidation-Reduction , Water/chemistry , Anti-Bacterial Agents , Hydrogen-Ion Concentration , Phosphates
7.
Food Microbiol ; 121: 104523, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38637085

ABSTRACT

This study investigated the fungicidal efficiency and mechanism of action of dielectric barrier discharge cold atmosphere plasma (DBD-CAP) in inactivating Aspergillus niger (A. niger) spores. The disinfection efficacy and quality of dried jujube used as the processing application object were also studied. The results indicated that the Weibull + Tail model performed better for spore inactivation curves at different voltages among various treatment times, and the spore cells were reduced by 4.05 log (cfu/mL) in spores suspension at 70 kV after 15 min of treatment. This disinfection impact was further supported by scanning electron microscope (SEM) and transmission electron microscopy (TEM) images, which showed that the integrity of the cell membrane was damaged, and the intracellular content leaked out after DBD-CAP treatment. Elevated levels of reactive oxygen species (ROS) during the treatment increased the relative conductivity of cells, and leakage of nucleic acids and proteins further supported the disinfection impact. Additionally, the growth and toxicity of surviving A. niger spores after treatment were also greatly reduced. When DBD-CAP was applied to disinfecting dried jujube, the spore number exhibited a 2.67 log cfu/g reduction after treatment without significant damage observed onto the quality (P > 0.05).


Subject(s)
Aspergillus , Plasma Gases , Ziziphus , Aspergillus niger , Plasma Gases/pharmacology , Disinfection/methods
8.
Front Public Health ; 12: 1335560, 2024.
Article in English | MEDLINE | ID: mdl-38638484

ABSTRACT

Objective: This study aimed to investigate the knowledge, attitude, and practice (KAP) regarding disinfection and hand hygiene, along with associated influencing factors among childcare facilities staff during the COVID-19 pandemic in Anhui, and to provide information for developing disinfection and hand hygiene strategies for childcare facilities. Methods: A web-based cross-sectional study was conducted among Anhui Province residents in China in September 2020. In this study, 60 childcare facilities in two cities of Anhui Province were selected using the convenient sampling method for questionnaires. The questionnaires were distributed through a web-based platform. The disinfection and hand hygiene KAP scores among childcare facilities staff were calculated, and their influencing factors were analyzed. The accuracy rates of knowledge, attitude, and practice of behavior were calculated and analyzed. Results: A total of 1,029 participants were included in the study. The disinfection and hand hygiene knowledge, attitude and practice ranged from approximately 5 to 23, 1 to 5, 3 to 13, respectively. The score of urban areas was higher than that of rural areas. Higher education levels and more years of working were associated with higher scores. Additionally, staff who received training or supervision had higher scores than those without. The categories with the lowest knowledge accuracy rate (46.3%), lowest attitude accuracy rate (4.2%), and "always" practice rate (5.3%) among childcare facility staff were all related to the question categories concerning the appropriate range of disinfectants for use. The accuracy rates of hand hygiene knowledge and attitude among the childcare facility staff were high (83.7%-99.6%), but the "always" practice rate was in the middle range (63.0%). Conclusion: The disinfection and hand hygiene knowledge among childcare facilities staff was inadequate during the COVID-19 pandemic in Anhui. Continuous implementation of education and training, particularly in rural areas, is essential. Establishing a monitoring system to assess usage effectiveness and adverse reactions in China is critical. Interventions should focus on increasing compliance with hand hygiene practices. Further research should explore the training and intervention of disinfection and hand hygiene, the safety of disinfection measures, and more operational hand hygiene methods in childcare facilities.


Subject(s)
COVID-19 , Hand Hygiene , Child , Humans , Hand Hygiene/methods , COVID-19/epidemiology , COVID-19/prevention & control , Cross-Sectional Studies , Child Care , Disinfection , Health Knowledge, Attitudes, Practice , Pandemics/prevention & control
9.
PLoS One ; 19(4): e0300355, 2024.
Article in English | MEDLINE | ID: mdl-38573892

ABSTRACT

In recent decades, minimally invasive surgery has become the favoured surgical technique, with increasing utilisation of robotic surgery to enhance patient outcomes. However, the design complexity of surgical robotic instruments can pose challenges in maintaining adequate cleaning, disinfection and sterilisation-particularly of the device's interior. In our hospital, robotic instruments are reused for a maximum of ten successive patients, following the manufacturer's guidelines. To the best of our knowledge, neither the manufacturer nor ISO standards have specified any methods to determine the sterility of robotic instruments after cleaning, disinfection and sterilisation procedures. In a small pilot study, we used a locally developed protocol to evaluate the sterility of 20 da Vinci SI robotic instruments, with the aim of determining whether the recommended cleaning, disinfection and sterilisation process is adequate to achieve safe usage in subsequent patients. None of the 20 instruments showed viable micro-organisms, therefore the robotic instruments were considered sterile, and suitable for re-use. We recommend our protocol to other hospitals, to be used as an essential control element in the assessment of their unique reprocessing technique for robotic instruments.


Subject(s)
Infertility , Robotic Surgical Procedures , Humans , Robotic Surgical Procedures/methods , Pilot Projects , Disinfection/methods , Minimally Invasive Surgical Procedures
10.
Oral Health Prev Dent ; 22: 151-158, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652288

ABSTRACT

PURPOSE: To investigate the effect of full-mouth disinfection on the sizes of the periodontal wound and periodontal inflammatory burden and whether it leads to a decrease in C-reactive protein (CRP) levels. MATERIALS AND METHODS: The study included 20 systemically healthy subjects (11 women and 9 men) 30 to 68 years old with localised or generalised periodontitis (stage III, grade C). The sizes of the periodontal wound and periodontal inflammatory burden were measured with the web application "Periodontalwound", which is based on measurements of average tooth cervices, as well as probing depths and bleeding on probing assessed at six sites around each tooth present in the oral cavity. The levels of hsCRP (high-sensitivity CRP) were measured with an immunochemical method. All three parameters were measured before initial treatment and 3 months after therapy. Full-mouth disinfection included removal of plaque and calculus with ultrasonic and hand instruments in one session. RESULTS: The results showed a statistically significant decrease in the size of the periodontal wound (p < 0.001), a statistically significant decrease in the size of periodontal inflammatory burden (p < 0.001), and a decrease in hsCRP levels 3 months after therapy. CONCLUSION: Full-mouth disinfection leads to a decrease in the periodontal wound and periodontal inflammatory burden size, as well as a decrease in the levels of hsCRP in patients with localised or generalised periodontitis (stage III, grade C).


Subject(s)
C-Reactive Protein , Disinfection , Humans , Male , Female , C-Reactive Protein/analysis , Middle Aged , Adult , Aged , Disinfection/methods , Periodontitis , Periodontal Index , Dental Plaque , Dental Calculus , Periodontal Pocket , Ultrasonic Therapy/methods
11.
J Hazard Mater ; 470: 134254, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38615644

ABSTRACT

The existence of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) has been a global public environment and health issue. Due to the different cell structures, gram-positive/negative ARB exhibit various inactivation mechanisms in water disinfection. In this study, a gram-negative ARB Escherichia coli DH5α (E. coli DH5α) was used as a horizontal gene transfer (HGT) donor, while a gram-positive ARB Bacillus as a recipient. To develop an efficient and engineering applicable method in water disinfection, ARB and ARGs removal efficiency of Fe(VI) coupled peroxydisulfate (PDS) or peroxymonosulfate (PMS) was compared, wherein hydroxylamine (HA) was added as a reducing agent. The results indicated that Fe(VI)/PMS/HA showed higher disinfection efficiency than Fe(VI)/PDS/HA. When the concentration of each Fe(VI), PMS, HA was 0.48 mM, 5.15 log E. coli DH5α and 3.57 log Bacillus lost cultivability, while the proportion of recovered cells was 0.0017 % and 0.0566 %, respectively, and HGT was blocked. Intracellular tetA was reduced by 2.49 log. Fe(IV) and/or Fe(V) were proved to be the decisive reactive species. Due to the superiority of low cost as well as high efficiency and practicality, Fe(VI)/PMS/HA has significant application potential in ARB, ARGs removal and HGT inhibition, offering a new insight for wastewater treatment.


Subject(s)
Gene Transfer, Horizontal , Iron , Peroxides , Peroxides/chemistry , Iron/chemistry , Water Purification/methods , Escherichia coli/drug effects , Escherichia coli/genetics , Drug Resistance, Bacterial/genetics , Disinfection/methods , Sulfates/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Bacillus/genetics , Bacillus/drug effects , Bacillus/metabolism
12.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38622548

ABSTRACT

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Subject(s)
Disinfectants , Disinfection , Humans , Disinfection/methods , Glutaral , Sodium Hypochlorite , Dental Impression Materials , Dental Impression Technique
13.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38608912

ABSTRACT

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Subject(s)
Disinfection , Drinking Water , Water Purification , Drinking Water/microbiology , Drinking Water/chemistry , Disinfection/methods , Water Purification/methods , Water Microbiology , Water Supply
14.
PLoS One ; 19(4): e0302258, 2024.
Article in English | MEDLINE | ID: mdl-38626152

ABSTRACT

Effective surface disinfection is crucial for preventing the spread of pathogens in hospitals. Standard UltraViolet-C (UV-C) lamps have been widely used for this purpose, but their disinfection efficiency under real-world conditions is not well understood. To fill this gap, the influence of the power of the ultraviolet radiator, source-sample distance, and exposure time on the performance of UV-C lamps against Escherichia coli and Staphylococcus epidermidis were experimentally determined in the laboratory and hospital. The obtained results showed that the UV irradiance and, thus, the UV-C disinfection efficiency decreased significantly at distances greater than 100 cm from the UV-C lamp. Moreover, increasing the total power of the radiators does not improve the performance of UV-C lamps under real conditions. The UV-C disinfection efficiency greater than 90% was achieved only under laboratory conditions at a close distance from the UV-C lamp, i.e., 10 cm. These findings provide novel insights into the limitations of UV-C lamps in real-world conditions and highlight the need for more effective disinfection strategies in hospitals.


Subject(s)
Escherichia coli , Ultraviolet Rays , Disinfection/methods
15.
BMC Oral Health ; 24(1): 416, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580975

ABSTRACT

OBJECTIVE: To investigate the status and related factors of sterilizers in dental health-care settings in Yunnan Province, with the aim of providing a theoretical basis for the health administrative department to formulate regional quality control programs and systems, proposing reasonable suggestions for optimizing the allocation of sterilizer resources in Yunnan's dental health-care settings, thereby improving resource utilization efficiency. METHODS: This cross-sectional survey was conducted in 2600 dental health-care settings in Yunnan Province in March 2020. Uni-variable linear regression, multi-variable linear regression, curve fitting and threshold effect analysis were used to understand the relationship between dental units and sterilizers. RESULTS: A total of 2600 dental health-care settings were included. The disinfection and sterilization work were mainly completed by the dental department in 1510(58.1%) institutions. 44(1.7%) institutions were not allocated sterilization equipment, and 1632 (62.8%) had only one sterilizer. The median allocation of sterilizers was 1.0. Uni-variable linear regression showed significant differences in covariates such as dental unit, dental handpiece, disinfection equipment, dentist, and dental assistant, which were more sensitive (p < 0.001) and statistically significant. The adjusted model was more stable in the multi-variable linear regression, and the differences in covariates between different settings were statistically significant. Curve fitting revealed an S-shaped curvilinear relationship between the number of dental units and sterilizers in oral healthcare settings. CONCLUSION: The disinfection and sterilization work was mainly completed by the dental department in dental health-care settings in Yunnan Province. Sterilizer allocation increases with the number of dental units, but some institutions have insufficient allocation of sterilizer and manpower resources, resulting in certain risks of infection control. Thus, it is necessary to strengthen supervision, inspection and regional quality control work in infection control of dentistry.


Subject(s)
Disinfection , Infection Control , Humans , Cross-Sectional Studies , China , Dental Instruments
16.
Appl Microbiol Biotechnol ; 108(1): 286, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578301

ABSTRACT

Ultraviolet-C light-emitting diodes (UV-C LEDs) are an emerging technology for decontamination applications in different sectors. In this study, the inactivation of bacterial biofilms was investigated by applying an UV-C LED emitting at 280 nm and by measuring both the influence of the initial cell density (load) and presence of an extracellular matrix (biofilm). Two bacterial strains exposing diverging matrix structures and biochemical compositions were used: Pseudomonas aeruginosa and Leuconostoc citreum. UV-C LED irradiation was applied at three UV doses (171 to 684 mJ/cm2) on both surface-spread cells and on 24-h biofilms and under controlled cell loads, and bacterial survival was determined. All surface-spread bacteria, between 105 and 109 CFU/cm2, and biofilms at 108 CFU/cm2 showed that bacterial response to irradiation was dose-dependent. The treatment efficacy decreased significantly for L. citreum surface-spread cells when the initial cell load was high, while no load effect was observed for P. aeruginosa. Inactivation was also reduced when bacteria were grown under a biofilm form, especially for P. aeruginosa: a protective effect could be attributed to abundant extracellular DNA and proteins in the matrix of P. aeruginosa biofilms, as revealed by Confocal Laser Scanning Microscopy observations. This study showed that initial cell load and exopolymeric substances are major factors influencing UV-C LED antibiofilm treatment efficacy. KEY POINTS: • Bacterial cell load (CFU/cm2) could impact UV-C LED irradiation efficiency • Characteristics of the biofilm matrix have a paramount importance on inactivation • The dose to be applied can be predicted based on biofilm properties.


Subject(s)
Biofilms , Disinfection , Extracellular Matrix , Bacteria , Extracellular Polymeric Substance Matrix , Pseudomonas aeruginosa
17.
J Coll Physicians Surg Pak ; 34(3): 364-367, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38462877

ABSTRACT

Nontuberculous Mycobacteria (NTM) commonly colonise municipal water supplies and cause healthcare-associated outbreaks. Although the infections are rare, they are associated with high mortality.  Aerosolization of NTM from colonised Heater cooler devices causes invasive infections in cardiac surgery patients. These units are widely used in open-chest heart surgery as an essential part of extracorporeal circulation but have been suggested as being a risk for infection.  Water disinfection as well as effective engineering-related mitigation strategies should be designed to decrease the burden of NTM in the hospital water supply. Key Words: Nontuberculous Mycobacteria, Heater cooler devices, Endocarditis, Water, Cardiothoracic surgeries.


Subject(s)
Cardiac Surgical Procedures , Nontuberculous Mycobacteria , Humans , Cardiac Surgical Procedures/adverse effects , Disinfection , Hospitals , Disease Outbreaks
18.
Sci Justice ; 64(2): 151-158, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38431372

ABSTRACT

Good laboratory practice minimizes the biological hazard posed by potentially infectious casework samples. In certain scenarios, when the casework sample is contaminated with highly contagious pathogens, additional safety procedures such as disinfection might be advised. It was previously proven that ozone gas treatment does not hamper STR analysis, but there is no data on how the disinfection affects other steps of the forensic analysis. In this study, we aimed to assess the interference of ozone disinfection with forensic tests used to identify biological stains. A dilution series of blood, saliva, and semen samples were pipetted onto cotton fabric and let completely dry. Half of the samples were subjected to ozone treatment, while the rest served as controls. All the samples were tested with specific lateral flow immunochromatographic assays and for specific RNA markers with quantitative real-time PCR. Additionally, luminol test was carried out on blood spots, Phadebas® Amylase Test on saliva stains, and semen stains were examined with STK Lab kit and light microscope following Christmas Tree or Hematoxylin-Eosin staining. Ozone treatment had no detrimental effect on the microscopic identification of sperm cells. Undiluted blood samples were detected with luminol and immunoassay, but at higher dilution, the sensitivity of the test decreased after disinfection. The same decrease in sensitivity was observed in the detection of semen stains using STK Lab kit from STK® Sperm Tracker, and in the case of the immunoassay specific for prostate-specific antigen (PSA). Ozone treatment almost completely inhibited the enzymatic activity of amylase. The sensitivity of antibody-based detection of amylase was also greatly reduced. RNA markers showed degradation but remained detectable in blood and semen samples after incubation in the presence of ozone. In saliva, the higher Ct values of the mRNA markers were close to the detection limit, even before ozone treatment.


Subject(s)
Blood Stains , Saliva , Humans , Male , Saliva/chemistry , Semen , Coloring Agents/analysis , Luminol/analysis , Disinfection , Amylases/analysis , RNA, Messenger/analysis , Staining and Labeling , Forensic Medicine/methods
19.
Br Dent J ; 236(5): 411, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38459328
20.
Huan Jing Ke Xue ; 45(3): 1561-1576, 2024 Mar 08.
Article in Chinese | MEDLINE | ID: mdl-38471870

ABSTRACT

At the time when water resources are in short supply,wastewater recycling is both an important environmental protection strategy and also a resource strategy. Disinfection is essential to ensure the biological safety of reclaimed wastewater by killing pathogens and preventing the spread of waterborne diseases. However,the disinfection process could inevitably produce toxic disinfection byproducts(DBPs)due to the reaction between the disinfectants and wastewater organic matters. Regarding wastewater DBPs,this study reviewed their identification methods,formation conditions(including precursors,the effect of water quality,disinfectants,and operational parameters on DBPs),and control methods(including source control,process control,and end control). In addition,future research trends of wastewater DBPs were discussed.


Subject(s)
Disinfectants , Water Pollutants, Chemical , Water Purification , Disinfection/methods , Wastewater , Water Purification/methods , Water Pollutants, Chemical/analysis , Halogenation
SELECTION OF CITATIONS
SEARCH DETAIL
...